{"id":716,"date":"2026-11-16T15:27:37","date_gmt":"2026-11-16T15:27:37","guid":{"rendered":"https:\/\/eazyclean.com\/%eb%93%9c%eb%9d%bc%ec%9d%b4%ed%81%b4%eb%a6%ac%eb%8b%9d-%ea%b8%b0%ea%b3%84%eb%8a%94-%ec%96%b4%eb%96%bb%ea%b2%8c-%ec%9e%91%eb%8f%99%ed%95%a0%ea%b9%8c%ec%9a%94\/"},"modified":"2026-11-16T16:18:23","modified_gmt":"2026-11-16T16:18:23","slug":"%eb%93%9c%eb%9d%bc%ec%9d%b4%ed%81%b4%eb%a6%ac%eb%8b%9d-%ea%b8%b0%ea%b3%84%eb%8a%94-%ec%96%b4%eb%96%bb%ea%b2%8c-%ec%9e%91%eb%8f%99%ed%95%a0%ea%b9%8c%ec%9a%94","status":"publish","type":"post","link":"https:\/\/eazyclean.com\/ko\/%eb%93%9c%eb%9d%bc%ec%9d%b4%ed%81%b4%eb%a6%ac%eb%8b%9d-%ea%b8%b0%ea%b3%84%eb%8a%94-%ec%96%b4%eb%96%bb%ea%b2%8c-%ec%9e%91%eb%8f%99%ed%95%a0%ea%b9%8c%ec%9a%94\/","title":{"rendered":"\ub4dc\ub77c\uc774\ud074\ub9ac\ub2dd \uae30\uacc4\ub294 \uc5b4\ub5bb\uac8c \uc791\ub3d9\ud560\uae4c\uc694?"},"content":{"rendered":"\n<div class=\"wp-block-group ez-kurzfassung\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<p class=\"ez-kurzfassung-titel\"><strong>Key takeaways<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>A dry cleaning machine washes in solvent and recovers nearly all of it before the door opens: by spinning, by condensing it out of the drying air and by distilling it.<\/li><li>One cycle: loading and door lock, solvent bath (about 3 l\/kg in the first bath), filtration, extraction at around 400 and then 600 rpm, closed-loop drying, distillation and aeration.<\/li><li>Distillation is the actual recovery step: the solvent boils, the soil does not. Hydrocarbon machines distil under vacuum at about 50\u2013100 mbar.<\/li><li>The bath is kept at about 26\u201328 \u00b0C so that the same programme gives the same result on load 40 as on load 1.<\/li><li>Daily care decides solvent consumption: strip the still, drain the water separator, empty the button trap.<\/li><\/ul>\n<\/div><\/div>\n\n<p>A dry cleaning machine washes textiles in a liquid solvent instead of water, then recovers nearly all of that solvent before the door opens \u2014 spinning it out of the fabric, condensing it out of the drying air, and boiling it clean again in a built-in still. The short answer to how does a dry cleaning machine work is that it is a washing machine with no drain.<\/p>\n\n<p>That is where most explanations stop. A domestic washer sends its dirty water to the sewer; a dry cleaning machine cannot. Its solvent is expensive, regulated and usually combustible, so every drop leaving the drum has to come back \u2014 and roughly two-thirds of what you are buying has nothing to do with washing.<\/p>\n\n<p>The machine is four loops sharing one drum: solvent through tanks and filters, a sealed air circuit through chiller and heater, a distillation circuit, and a monitoring circuit of sensors and interlocks. A washing machine has one. For the customer&#8217;s view, see <a href=\"https:\/\/eazyclean.com\/ko\/%eb%93%9c%eb%9d%bc%ec%9d%b4%ed%81%b4%eb%a6%ac%eb%8b%9d%ec%9d%80-%ec%96%b4%eb%96%bb%ea%b2%8c-%ec%9d%b4%eb%a3%a8%ec%96%b4%ec%a7%80%eb%82%98%ec%9a%94\/\">how dry cleaning works<\/a>.<\/p>\n\n<h2 class=\"wp-block-heading\">Step 1: Loading, door lock, pre-checks<\/h2>\n\n<p>Goods are sorted by colour and fabric and weighed. Overloading is the most common operator error: a drum packed too full cannot lift and drop the load, the mechanical action collapses, and the goods come out grey.<\/p>\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"579\" src=\"https:\/\/eazyclean.com\/wp-content\/uploads\/2026\/10\/loading-garments-dry-cleaning-machine-ec-115-ai-1024x579.webp\" alt=\"Garments being loaded into the open drum of an EC 115 dry cleaning machine by EazyClean Technologies\" class=\"wp-image-560\" srcset=\"https:\/\/eazyclean.com\/wp-content\/uploads\/2026\/10\/loading-garments-dry-cleaning-machine-ec-115-ai-1024x579.webp 1024w, https:\/\/eazyclean.com\/wp-content\/uploads\/2026\/10\/loading-garments-dry-cleaning-machine-ec-115-ai-300x170.webp 300w, https:\/\/eazyclean.com\/wp-content\/uploads\/2026\/10\/loading-garments-dry-cleaning-machine-ec-115-ai-768x434.webp 768w, https:\/\/eazyclean.com\/wp-content\/uploads\/2026\/10\/loading-garments-dry-cleaning-machine-ec-115-ai-1536x869.webp 1536w, https:\/\/eazyclean.com\/wp-content\/uploads\/2026\/10\/loading-garments-dry-cleaning-machine-ec-115-ai.webp 1600w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Loading by weight, not by eye: an overfilled drum cannot lift and drop the load.<\/figcaption><\/figure>\n\n<p>The door is a pressure-tight closure with a gasket, not a domestic bellows seal. Once it shuts, the control runs a checklist: solvent level in the working tank, still temperature, filter differential pressure, button-trap and lint-filter seating, water-separator seal. On a typical machine the door locks after about one minute of standstill. EazyClean Technologies machines carry <strong>30 integrated measuring points<\/strong> that monitor every cycle in real time; the control will not start a run it cannot complete safely.<\/p>\n\n<h2 class=\"wp-block-heading\">Step 2: Solvent inlet, bath ratio, circulation<\/h2>\n\n<p>Solvent is pumped from a tank into the shell around the perforated drum to a set level. The quantity is the <strong>bath ratio<\/strong> \u2014 litres of solvent per kilogram of goods. German trade practice for a two-bath programme is roughly <strong>3 l\/kg for the first bath and 5 l\/kg for the second<\/strong>; Wikipedia describes the same thing from outside as a chamber filled about one-third. Level sensors matched to the actual load save real energy, because everything you put in you later have to distil out again.<\/p>\n\n<p>Two baths, not one, is standard for anything but light soiling. The first dissolves and gets dirty; the second is a rinse in freshly distilled solvent that stops soil suspended in the first bath from redepositing as the solvent drains. That is why a real machine has <strong>two or three separate tanks<\/strong> \u2014 working, rinse, clean-distilled; a typical three-tank machine uses around 60, 80 and 100 litres.<\/p>\n\n<p>Detergent goes into the bath, not onto the goods: typically <strong>0.5 to 1.25 %<\/strong>, emulsifying water-soluble soil and holding loosened dirt in suspension. Throughout, a pump keeps solvent moving through the filters.<\/p>\n\n<h2 class=\"wp-block-heading\">Step 3: Mechanical action, and why the drum behaves differently<\/h2>\n\n<p>The drum turns slowly and reverses. A typical pattern is <strong>13 seconds of rotation, a 4-second pause<\/strong>, then the same the other way. The pause lets the load fall apart before the ribs pick it up again, which prevents roping in a bath with almost no surface tension to hold garments open.<\/p>\n\n<p>The speed is set by physics. Goods pin themselves to the drum wall once centrifugal acceleration reaches 1 g, which for a drum of diameter <em>D<\/em> in metres happens at about 42.3 \/ \u221a<em>D<\/em> rpm \u2014 roughly 47 rpm for an 0.8 m drum, 42 rpm for a 1 m drum. Wash agitation stays well below that, so it lives in the <strong>tens of rpm, not the hundreds<\/strong>. Published figures vary by manufacturer and solvent; treat any single number as that machine&#8217;s.<\/p>\n\n<p>Three things make the mechanics unlike water washing. <strong>Solvents do not swell fibres<\/strong> \u2014 water swells cellulose and protein fibres, and that swelling plus water&#8217;s surface tension produces felting, shrinkage and set creases, which is why a tailored jacket survives solvent with its canvas intact and why the mechanics can afford to be gentle. <strong>Buoyancy differs<\/strong>: perchloroethylene has a density around 1.62 g\/ml, hydrocarbon 0.78, water 1.00, so in perc the bath carries part of the load&#8217;s weight and in hydrocarbon it does not. <strong>There is almost no surface tension<\/strong>, so solvent wets and drains instantly \u2014 no soak phase, and the useful work happens in the first minutes.<\/p>\n\n<p>The times follow: in a two-bath programme the first bath runs about <strong>6 minutes<\/strong>, the second about <strong>18<\/strong>. Wikipedia gives a general range of 3\u201315 minutes and notes hydrocarbon machines need at least 25 \u2014 both are right, for different solvents.<\/p>\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"579\" src=\"https:\/\/eazyclean.com\/wp-content\/uploads\/2026\/10\/dry-cleaning-machine-drum-solvent-bath-ai-1024x579.webp\" alt=\"Garments turning in clear solvent behind the door glass of an EC 115 by EazyClean Technologies\" class=\"wp-image-563\" srcset=\"https:\/\/eazyclean.com\/wp-content\/uploads\/2026\/10\/dry-cleaning-machine-drum-solvent-bath-ai-1024x579.webp 1024w, https:\/\/eazyclean.com\/wp-content\/uploads\/2026\/10\/dry-cleaning-machine-drum-solvent-bath-ai-300x170.webp 300w, https:\/\/eazyclean.com\/wp-content\/uploads\/2026\/10\/dry-cleaning-machine-drum-solvent-bath-ai-768x434.webp 768w, https:\/\/eazyclean.com\/wp-content\/uploads\/2026\/10\/dry-cleaning-machine-drum-solvent-bath-ai-1536x869.webp 1536w, https:\/\/eazyclean.com\/wp-content\/uploads\/2026\/10\/dry-cleaning-machine-drum-solvent-bath-ai.webp 1600w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">The solvent wets the load at once. The drum turns slowly and reverses.<\/figcaption><\/figure>\n\n<h2 class=\"wp-block-heading\">Step 4: Filtration while the machine runs<\/h2>\n\n<p>Filtration is continuous during the bath, in stages, coarsest first.<\/p>\n\n<p><strong>Button trap<\/strong> \u2014 a strainer basket in the solvent line catching buttons, coins, pins and pocket debris. It protects the pump, not the garments; emptied by hand every 8\u201310 cycles, as manufacturer manuals typically specify.<\/p>\n\n<p><strong>Lint filter<\/strong> \u2014 a screen or mat taking the fibre shed by the load. Lint that gets past ends up in the still and in the residue, where it costs solvent.<\/p>\n\n<p><strong>Cartridge filter<\/strong> \u2014 the working filter. Modern cartridges combine a particulate stage with activated carbon and clays, taking both the pigment dirt that greys goods and the dissolved fatty acids and loose dyes that dull them. They are changed on <strong>differential pressure<\/strong>, not on a calendar: manufacturer manuals typically specify around 1.8 bar. Past that limit a cartridge has stopped filtering and started throttling the pump.<\/p>\n\n<p><strong>Spin-disc filter<\/strong> \u2014 the alternative on larger machines: a disc stack cleaned by centrifugal force, producing a solid cake the trade calls <em>muck<\/em> instead of spent cartridges.<\/p>\n\n<p>Filtration removes what is suspended. It does not remove what is dissolved, and it does not remove water.<\/p>\n\n<h2 class=\"wp-block-heading\">Step 5: Extraction<\/h2>\n\n<p>The bath drains back to a tank and the drum accelerates. Most programmes spin twice: an <strong>intermediate spin around 400 rpm<\/strong> (roughly 70 g) and a <strong>final spin around 600 rpm<\/strong> (roughly 165 g); Wikipedia gives 350\u2013450 rpm as the general range.<\/p>\n\n<p>Mechanical extraction is the cheapest solvent recovery there is \u2014 every gram thrown out here need not be evaporated and re-condensed later, and drying is where the energy goes.<\/p>\n\n<h2 class=\"wp-block-heading\">Step 6: Drying in a closed loop<\/h2>\n\n<p>After the spin the goods still hold solvent. Drying removes it \u2014 and, critically, keeps it.<\/p>\n\n<p>Warm air enters the drum at up to about <strong>75 \u00b0C<\/strong> depending on solvent and load; Wikipedia gives the air around the goods as 60\u201363 \u00b0C. Nobody heats the solvent itself. The air leaves loaded with vapour and passes a <strong>refrigerated condenser<\/strong>, where the vapour condenses into a trough; the air, now dry and cold, is reheated and returned to the drum. It never reaches the room. That loop is what &#8220;closed circuit&#8221; means.<\/p>\n\n<p>The condensate is not pure solvent \u2014 it is solvent plus the water that came in with the goods and the air. Separating them is the job of the <strong>water separator<\/strong>, a gravity vessel exploiting the density difference: with perc (1.62 g\/ml) the water floats off the top, with hydrocarbon (0.78 g\/ml) it sinks and is drawn from the bottom. It must be drained daily; a flooded separator pushes water back into the working tank, causing shrinkage and dye bleeding that then gets blamed on the programme.<\/p>\n\n<p>Drying with cool-down runs about <strong>35 to 40 minutes<\/strong>; full cycles run roughly 45 minutes for perc, 50\u201365 for hydrocarbon, 62\u201370 for K4. Vacuum drying lowers the boiling point of residual solvent so it leaves the fabric cooler.<\/p>\n\n<h2 class=\"wp-block-heading\">Step 7: Distillation, the actual recovery step<\/h2>\n\n<p>Any complete answer to how does a dry cleaning machine work has to include the still, and this is the part consumer articles skip.<\/p>\n\n<p>Filters remove particles. They cannot remove dissolved fats, oils, waxes, loose dyes and non-volatile residues, which accumulate bath after bath until the solvent itself is the source of the greying. Distillation removes them using the one property that separates solvent from soil: <strong>the solvent boils, the soil does not.<\/strong><\/p>\n\n<p>Used solvent is fed into a boiler and heated by steam or an electric element until it vaporises. The vapour rises, leaving contaminants behind, passes a cooled condenser and returns to liquid, then goes through the water separator into the <strong>clean solvent tank<\/strong> \u2014 the tank the rinse bath draws from.<\/p>\n\n<p>The numbers depend on the solvent. <strong>Perchloroethylene<\/strong> boils at 121 \u00b0C and distils at atmospheric pressure; on a typical three-tank machine the control cuts distillation at 135 \u00b0C, cuts stripping at 138 \u00b0C (steam) or 145 \u00b0C (electric), and the distillate returns at about 55 \u00b0C. <strong>Hydrocarbon<\/strong> boils at 180\u2013210 \u00b0C and <strong>SOLVONK4<\/strong> at 180.5 \u00b0C \u2014 boiling those at atmospheric pressure would mean running a combustible liquid near 200 \u00b0C inside a textile machine. So hydrocarbon and K4 machines distil <strong>under vacuum<\/strong>, typically around <strong>50 to 100 mbar absolute<\/strong>, which drops the boiling point far enough to be safe and gentle on the solvent.<\/p>\n\n<p>What stays behind is the <strong>distillation residue<\/strong> \u2014 a dark, oily sludge of fats, dyes, non-volatile residues and lint, still carrying solvent; Kreussler puts the residual solvent content of K4 residue at <strong>35 to 45 %<\/strong>. It is hazardous waste in most jurisdictions. Stripping the still is a <strong>daily<\/strong> task, and machine manuals state plainly that skipping it reduces distillation performance and raises solvent consumption \u2014 which is how a neglected machine quietly becomes expensive.<\/p>\n\n<p>Machines with continuous distillation \u2014 distilling part of the solvent during every cycle rather than in batch runs \u2014 hold the bath cleaner. EazyClean Technologies machines carry integrated distillation and filtration with <strong>99.9 % solvent recovery<\/strong> in a fully closed hydrocarbon circuit.<\/p>\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"717\" src=\"https:\/\/eazyclean.com\/wp-content\/uploads\/2026\/10\/closed-solvent-circuit-dry-cleaning-machine-diagram-1024x717.webp\" alt=\"Diagram of the closed solvent circuit in a hydrocarbon dry cleaning machine: drum, filters, working tank, clean tank, vacuum still, separator, heater and chiller\" class=\"wp-image-574\" srcset=\"https:\/\/eazyclean.com\/wp-content\/uploads\/2026\/10\/closed-solvent-circuit-dry-cleaning-machine-diagram-1024x717.webp 1024w, https:\/\/eazyclean.com\/wp-content\/uploads\/2026\/10\/closed-solvent-circuit-dry-cleaning-machine-diagram-300x210.webp 300w, https:\/\/eazyclean.com\/wp-content\/uploads\/2026\/10\/closed-solvent-circuit-dry-cleaning-machine-diagram-768x538.webp 768w, https:\/\/eazyclean.com\/wp-content\/uploads\/2026\/10\/closed-solvent-circuit-dry-cleaning-machine-diagram-1536x1075.webp 1536w, https:\/\/eazyclean.com\/wp-content\/uploads\/2026\/10\/closed-solvent-circuit-dry-cleaning-machine-diagram.webp 1600w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Simplified circuit of a hydrocarbon machine: used solvent goes to the vacuum still, clean solvent returns to the clean tank.<\/figcaption><\/figure>\n\n<h2 class=\"wp-block-heading\">Step 8: Deodorising and aeration<\/h2>\n\n<p>Drying gets the bulk of the solvent out. It does not get the last of it, and the last of it is what the customer smells.<\/p>\n\n<p>The aeration phase circulates cool air through the goods, and on most machines that air passes an <strong>activated carbon adsorber<\/strong> \u2014 carbon plus polymer resins \u2014 which holds the residual vapour. The carbon is later desorbed with steam or hot air, and what comes off is condensed back into the solvent circuit: recovery, not waste.<\/p>\n\n<p>The door will not open until vapour concentration in the drum falls below a threshold \u2014 in the US commonly <strong>300 ppm<\/strong>, enforced by an interlock on fourth- and fifth-generation machines. In Germany the 2. BImSchV requires perc machines to reach <strong>2 g per cubic metre of machine air<\/strong> before unloading; hydrocarbon machines fall under the 31. BImSchV.<\/p>\n\n<h2 class=\"wp-block-heading\">Why the solvent is cooled<\/h2>\n\n<p>The bath is kept cold on purpose \u2014 trade practice holds solvent at roughly <strong>26\u201328 \u00b0C (78\u201382 \u00b0F)<\/strong>, using cooling coils in the base tanks and jackets on the lines.<\/p>\n\n<p>Solvent power rises with temperature. Aggressiveness is measured by the <strong>KB value<\/strong>, the Kauri-Butanol number, which describes how much resin a solvent dissolves: perc 90, SOLVONK4 75, hydrocarbon 25\u201345, siloxane D5 about 13. Those are values at working temperature; let the bath warm and the <em>effective<\/em> KB value climbs with it. The first thing a more aggressive bath does is strip dye from one garment onto another, wool and silk first.<\/p>\n\n<p>Cooling therefore does not improve cleaning in the sense of dissolving more soil. It does the opposite, deliberately, and what it buys is <strong>predictability<\/strong>: the same programme gives the same result on load 40 as on load 1, instead of getting harsher as the machine&#8217;s waste heat and 55 \u00b0C distillate warm the tanks.<\/p>\n\n<h2 class=\"wp-block-heading\">&#8220;Basically a giant front-load washing machine&#8221;<\/h2>\n\n<p>That description comes up again and again in short videos shot inside working dry cleaning shops. It is not wrong about what you can see, and the people filming run these machines every day. What a camera cannot show is everything downstream of the drum:<\/p>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>A washing machine has<\/th><th>A dry cleaning machine also has<\/th><\/tr><\/thead><tbody><tr><td>One water inlet, one drain<\/td><td>Two or three solvent tanks and no drain at all<\/td><\/tr><tr><td>A pump-out to the sewer<\/td><td>A pump-around through button trap, lint filter and cartridge<\/td><\/tr><tr><td>A vented dryer, or a condenser to a tank<\/td><td>A sealed air loop with refrigerated condenser and carbon adsorber<\/td><\/tr><tr><td>\u2014<\/td><td>A distillation still with boiler, condenser and residue vessel<\/td><\/tr><tr><td>\u2014<\/td><td>A water separator working on a density difference<\/td><\/tr><tr><td>A door lock on water level<\/td><td>A door lock on solvent vapour concentration<\/td><\/tr><tr><td>Painted steel and plastic<\/td><td>Austenitic stainless steel on every solvent-wetted part<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p>The washing is the part that is easy to film and the part that costs least. Everything else \u2014 how completely the filters catch what they should, how cleanly the still separates solvent from residue \u2014 is the part of how does a dry cleaning machine work that no video from the shop floor can show.<\/p>\n\n<h2 class=\"wp-block-heading\">Types of dry cleaning machines<\/h2>\n\n<p>The industry classifies machines by <strong>generation<\/strong>, and the generation tells you where the solvent goes.<\/p>\n\n<ul class=\"wp-block-list\"><li><strong>First generation (transfer, to the late 1960s).<\/strong> Two units, wet transfer by hand between them, vapours to atmosphere. Obsolete.<\/li><li><strong>Second generation (dry-to-dry, vented).<\/strong> Wash and dry in one drum \u2014 goods go in dry and come out dry \u2014 but still vented outside.<\/li><li><strong>Third generation.<\/strong> Dryer exhaust routed to a <strong>refrigerated condenser<\/strong> instead of a vent. The first genuinely closed circuit.<\/li><li><strong>Fourth generation.<\/strong> Condenser <strong>plus carbon adsorber<\/strong>, and a door interlock holding the drum shut until vapour falls below the limit.<\/li><li><strong>Fifth generation.<\/strong> Vapour sensors, with the lockout extended to button trap and filter housings.<\/li><\/ul>\n\n<p>Anything sold new in a regulated market today is fourth or fifth generation. On a used machine, the generation is the first question, before drum size.<\/p>\n\n<p>Machines also divide by <strong>solvent class<\/strong>, and this is not a soft distinction. <strong>Class IIIA machines<\/strong> are built for combustible solvents \u2014 flash point at or above 60 \u00b0C (140 \u00b0F) and below 93 \u00b0C (200 \u00b0F) \u2014 with the electrical, ventilation and interlock design that class demands; perc machines carry none of those provisions. The requirements are standardised as <strong>ISO 8230-1<\/strong> (all machines), <strong>-2<\/strong> (perchloroethylene) and <strong>-3<\/strong> (combustible solvents). A machine certified for one class is not converted to another by changing what you pour in.<\/p>\n\n<p>Beyond that, machines split by mounting \u2014 <strong>hard-mounted<\/strong>, limited by what the building tolerates, versus <strong>suspended<\/strong>, which absorbs imbalance internally and spins harder \u2014 and by drum capacity, from about 8 kg upward. The EazyClean Technologies <a href=\"https:\/\/eazyclean.com\/products\/ec-series\/\">EC series<\/a> reaches <strong>35 kg<\/strong> for multi-shift operation; the <a href=\"https:\/\/eazyclean.com\/products\/smart-series\/\">SMART series<\/a> is the smaller entry point.<\/p>\n\n<p>A <strong>wet cleaning<\/strong> installation is a different machine: a computer-controlled washer-extractor plus a tensioning dryer, running water with specialised detergents and tightly limited mechanical action and moisture. It carries the <strong>W<\/strong> care symbol, not P or F, and it fails on the heavy oils and greases solvent handles best. Most operations run both; no single drum does both jobs.<\/p>\n\n<h2 class=\"wp-block-heading\">What is dry cleaning solvent?<\/h2>\n\n<p>A dry cleaning solvent is a <strong>non-aqueous liquid that dissolves oils, fats and greases without swelling textile fibres<\/strong>. That is the whole trick: water is an excellent solvent for salts and sugars, a poor one for fat, and it wrecks fibre geometry on the way through. Solvents are the reverse \u2014 which is why they need a detergent added to handle water-soluble soil at all.<\/p>\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Solvent<\/th><th>Class<\/th><th>KB value<\/th><th>Boiling point<\/th><th>Flash point<\/th><th>Care symbol<\/th><\/tr><\/thead><tbody><tr><td>Perchloroethylene (perc, PCE)<\/td><td>Chlorinated<\/td><td>90<\/td><td>121 \u00b0C<\/td><td>none (non-flammable)<\/td><td>P in a circle<\/td><\/tr><tr><td>Hydrocarbon (DF-2000, EcoSolv, ShellSol)<\/td><td>Aliphatic hydrocarbon<\/td><td>25\u201345<\/td><td>180\u2013210 \u00b0C<\/td><td>57\u201364 \u00b0C, Class IIIA<\/td><td>F in a circle<\/td><\/tr><tr><td>SOLVONK4 (dibutoxymethane \/ butylal)<\/td><td>Acetal<\/td><td>75<\/td><td>180.5 \u00b0C<\/td><td>62 \u00b0C, Class IIIA<\/td><td>no dedicated ISO symbol<\/td><\/tr><tr><td>Siloxane D5 (GreenEarth)<\/td><td>Cyclic siloxane<\/td><td>~13<\/td><td>\u2014<\/td><td>76 \u00b0C (170 \u00b0F), Class IIIA<\/td><td>F in a circle<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p><em>Figures from Kreussler, American Drycleaner and Wikipedia; check the product safety data sheet before commissioning.<\/em><\/p>\n\n<p><strong>Perchloroethylene<\/strong> cleans hardest and is non-flammable, which is why it dominated for eighty years. It is also under sustained regulatory pressure in Europe and North America; the direction of travel is away from it, but the rules differ by country and keep changing, so check your own jurisdiction. <strong>Hydrocarbon<\/strong> is the mainstream alternative, and what EazyClean Technologies builds around: gentler on fibres and dyes, at the cost of longer cycles, combustible, and high-boiling \u2014 which is why those machines distil under vacuum. <strong>SOLVONK4<\/strong> is a bipolar acetal handling mixed soil better than a pure hydrocarbon. <strong>Siloxane D5<\/strong> is the gentlest, and at a KB value near 13 that gentleness is its limit: it struggles with oils, and its regulatory position under EU REACH should be checked before choosing it.<\/p>\n\n<p>On the care label the <strong>circle<\/strong> is the professional-textile-care symbol under ISO 3758 and the GINETEX system. <strong>P<\/strong> means perchloroethylene, with hydrocarbon also permitted; <strong>F<\/strong> means hydrocarbon only; <strong>W<\/strong> means professional wet cleaning; a <strong>bar under the circle<\/strong> means a mild process \u2014 less mechanical action, less moisture, lower drying temperature. A crossed-out circle means do not dry clean, and no machine setting overrides it. How the two main solvents compare in practice is covered in <a href=\"https:\/\/eazyclean.com\/ko\/%ed%83%84%ed%99%94%ec%88%98%ec%86%8c-%eb%93%9c%eb%9d%bc%ec%9d%b4%ed%81%b4%eb%a6%ac%eb%8b%9d-%ea%b8%b0%ea%b3%84%ec%99%80-%ed%8d%bc%ed%81%acperc-%ec%96%b4%eb%8a%90-%ec%aa%bd%ec%9d%84-%ec%84%a0\/\">hydrocarbon or perc<\/a>.<\/p>\n\n<h2 class=\"wp-block-heading\">Maintenance, safety, emissions, service life<\/h2>\n\n<p><strong>Daily:<\/strong> strip the still and remove the distillation residue; drain the water separator trap; empty the button trap; clean the lint filter; check for leaks and check the solvent safety trough. <strong>Weekly:<\/strong> empty and clean the water separator; wash the lint filter mat; clean spray nozzles; run the carbon-adsorber maintenance programme. <strong>By condition:<\/strong> change the cartridge filter on differential pressure; service the refrigeration circuit; check gaskets and seals.<\/p>\n\n<p>Every item on that list is a solvent-consumption item. A still that is not stripped distils worse; a flooded separator puts water into the bath. None of these raise an alarm \u2014 they surface as rising solvent consumption and falling quality, which is why dense instrumentation earns its keep.<\/p>\n\n<p>Safety is layered: the vapour interlock on the door, extended interlocks on filter housings, the catch trough, temperature cut-outs on the still, and on combustible-solvent machines the ventilation and inerting provisions of ISO 8230-3. Emissions come down to residual solvent in the goods, in the distillation residue, and leakage \u2014 which is why solvent consumption per kilogram is simultaneously the operating cost, the environmental figure and the compliance figure. They are one number.<\/p>\n\n<p>On service life: on a well-built machine every solvent-wetted part is austenitic stainless steel \u2014 V2A\/V4A, equivalent to 304\/316 \u2014 because solvent, detergent and trace water find any weakness. EazyClean Technologies machines have a service life of <strong>20 to 30 years<\/strong>, a figure that only means something alongside the list above.<\/p>\n\n<h2 class=\"wp-block-heading\">Where EazyClean Technologies fits<\/h2>\n\n<p>EazyClean Technologies builds hydrocarbon machines in Herten, North Rhine-Westphalia: integrated distillation and filtration, solvent cooling, 30 measuring points per cycle, over 80 programmes, touchscreen control with automatic detergent dosing, 99.9 % solvent recovery in a fully closed circuit. As of September 2026, the SMART series starts at 65,770 EUR net ex works, the EC series \u2014 EC115, EC124, EC135 \u2014 at 83,990 EUR net ex works, depending on drum size, specification and site connections. <a href=\"https:\/\/eazyclean.com\/products\/used-machines\/\">Reconditioned machines<\/a> are checked and refurbished before sale, and a complete first fit-out also needs a finisher, a spotting table and the required extraction. The full budget is set out in <a href=\"https:\/\/eazyclean.com\/ko\/%eb%93%9c%eb%9d%bc%ec%9d%b4%ed%81%b4%eb%a6%ac%eb%8b%9d-%ea%b8%b0%ea%b3%84-%ea%b0%80%ea%b2%a9%ec%9d%80-%ec%96%bc%eb%a7%88%ec%9d%b8%ea%b0%80%ec%9a%94\/\">how much a dry cleaning machine costs<\/a>. The whole plant is covered in <a href=\"https:\/\/eazyclean.com\/ko\/%eb%93%9c%eb%9d%bc%ec%9d%b4%ed%81%b4%eb%a6%ac%eb%8b%9d-%ec%82%ac%ec%97%85-%ec%8b%9c%ec%9e%91-%eb%b0%a9%eb%b2%95-%ec%9e%a5%eb%b9%84-%ea%b3%b5%ea%b0%84-%ed%97%88%ea%b0%80-%eb%b0%8f-%ec%9e%90%eb%b3%b8\/\">how to start a dry cleaning business<\/a>.<\/p>\n\n<h2 class=\"wp-block-heading\">FAQ<\/h2>\n\n<p><strong>How does a dry cleaning machine work, in short?<\/strong> Goods go into a sealed drum dry. Solvent floods it at 3\u20135 litres per kilogram, the drum reverses slowly while a pump circulates solvent through filters, the bath drains, the drum spins at 400\u2013600 rpm, warm air in a closed loop evaporates the rest while a chiller condenses it, and a still boils it clean.<\/p>\n\n<p><strong>Is a dry cleaning machine just a washing machine that uses chemicals?<\/strong> No. A washing machine drains to the sewer. A dry cleaning machine has no drain \u2014 every drop must be recovered through filtration, distillation and condensation. Roughly two-thirds of the hardware serves recovery: a still, a water separator, a refrigerated condenser, a carbon adsorber.<\/p>\n\n<p><strong>What does the distillation unit actually do?<\/strong> It separates solvent from dissolved soil by boiling. The solvent vaporises, rises and condenses back to clean liquid; fats, oils, waxes, dyes and non-volatile residues stay behind in the boiler. Filters only remove suspended particles. Without distillation, dissolved soil builds up until the solvent makes garments grey.<\/p>\n\n<p><strong>How long is a full cycle?<\/strong> Roughly 45 minutes on a perchloroethylene machine, 50\u201365 minutes on hydrocarbon and 62\u201370 minutes on a K4 machine, of which drying takes 28 to 48 minutes. Hydrocarbon needs longer because it dissolves more slowly and boils higher. Load size and soiling shift every one of those figures.<\/p>\n\n<p><strong>Why is the solvent kept cold?<\/strong> Because solvent power rises with temperature. A warm bath behaves like a more aggressive solvent, and the first thing that does is strip dye from one garment onto another \u2014 wool and silk first. Holding the bath near 26\u201328 \u00b0C keeps results consistent from the first load to the last.<\/p>\n\n<p><strong>What are the main types of dry cleaning machines?<\/strong> By generation: transfer machines, vented dry-to-dry, closed circuit with refrigerated condenser, closed circuit with carbon adsorber and door interlock, and fifth generation with vapour sensors and extended lockouts. By solvent class: perchloroethylene machines under ISO 8230-2, Class IIIA combustible-solvent machines under ISO 8230-3.<\/p>\n\n<p><strong>What is dry cleaning solvent, and which one should a machine use?<\/strong> A non-aqueous liquid that dissolves grease without swelling fibres. Perchloroethylene cleans hardest and is under regulatory pressure; hydrocarbon is the mainstream alternative, gentler on dyes, combustible, needing a Class IIIA machine; K4 handles mixed soil; D5 is gentlest and weakest on oils. The machine is built around the class, not the reverse.<\/p>\n\n<p><strong>How long does a dry cleaning machine last?<\/strong> EazyClean Technologies machines have a service life of 20 to 30 years, which is realistic where the solvent-wetted parts are austenitic stainless steel. That assumes the daily routine is done: stripping the still, draining the water separator, emptying the button trap, changing cartridges on pressure.<\/p>\n\n<h2 class=\"wp-block-heading\">Sources<\/h2>\n\n<ul class=\"wp-block-list\"><li>Wikipedia: <a href=\"https:\/\/en.wikipedia.org\/wiki\/Dry_cleaning\">Dry cleaning<\/a><\/li><li>Kreussler Chemie: <a href=\"https:\/\/en.kreussler-chemie.com\/customers\/textile_cleaners\/systemk4\/faq.html\">SYSTEMK4: frequently asked questions<\/a><\/li><li>Energiesparhandbuch: <a href=\"http:\/\/www.energiesparhandbuch.de\/inhalt\/maschinen-und-verfahren-in-der-textilreinigung\/maschinentechnik.html\">Maschinentechnik in der Textilreinigung (German)<\/a><\/li><li>EnviroForensics: <a href=\"https:\/\/www.enviroforensics.com\/blog\/the-history-of-dry-cleaning-solvents-and-the-evolution-of-the-dry-cleaning-machine\/\">The history of dry cleaning solvents and the evolution of the dry cleaning machine<\/a><\/li><li>American Drycleaner: <a href=\"https:\/\/americandrycleaner.com\/articles\/alternative-solvents-which-best-you-part-1\">Alternative solvents: which is best for you? Part 1<\/a><\/li><li>American Drycleaner: <a href=\"https:\/\/americandrycleaner.com\/articles\/alternative-solvents-which-best-you-part-2\">Alternative solvents: which is best for you? Part 2<\/a><\/li><li>ISO: <a href=\"https:\/\/www.iso.org\/standard\/38071.html\">ISO 8230-1:2008, safety requirements for dry-cleaning machines, part 1<\/a><\/li><li>GINETEX: <a href=\"https:\/\/www.ginetex.net\/gb\/labelling\/care-symbols.asp\">Care symbols<\/a><\/li><li>gesetze-im-internet.de: <a href=\"https:\/\/www.gesetze-im-internet.de\/bimschv_2_1990\/\">2. BImSchV (German)<\/a><\/li><li>UpCodes: <a href=\"https:\/\/up.codes\/s\/dry-cleaning-solvent-classifications\">Dry cleaning solvent classifications<\/a><\/li><\/ul>\n","protected":false},"excerpt":{"rendered":"<p>\ub4dc\ub77c\uc774\ud074\ub9ac\ub2dd \uae30\uacc4\ub294 \uc5b4\ub5bb\uac8c \uc791\ub3d9\ud560\uae4c\uc694? \ud55c \uae30\uacc4 \uc81c\uc870\uc5c5\uccb4\uac00 \uc6a9\uc81c \uc695\uc870, \uc5ec\uacfc, \ud0c8\uc218, \ud3d0\uc1c4\ud615 \uac74\uc870, \uc99d\ub958\uc5d0 \uc774\ub974\ub294 \uc804\uccb4 \uacf5\uc815\uc744 \ub2e8\uacc4\ubcc4\ub85c \uc124\uba85\ud569\ub2c8\ub2e4.<\/p>\n","protected":false},"author":1,"featured_media":717,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[44],"tags":[],"class_list":["post-716","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-44"],"_links":{"self":[{"href":"https:\/\/eazyclean.com\/ko\/wp-json\/wp\/v2\/posts\/716","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/eazyclean.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/eazyclean.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/eazyclean.com\/ko\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/eazyclean.com\/ko\/wp-json\/wp\/v2\/comments?post=716"}],"version-history":[{"count":4,"href":"https:\/\/eazyclean.com\/ko\/wp-json\/wp\/v2\/posts\/716\/revisions"}],"predecessor-version":[{"id":832,"href":"https:\/\/eazyclean.com\/ko\/wp-json\/wp\/v2\/posts\/716\/revisions\/832"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/eazyclean.com\/ko\/wp-json\/wp\/v2\/media\/717"}],"wp:attachment":[{"href":"https:\/\/eazyclean.com\/ko\/wp-json\/wp\/v2\/media?parent=716"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/eazyclean.com\/ko\/wp-json\/wp\/v2\/categories?post=716"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/eazyclean.com\/ko\/wp-json\/wp\/v2\/tags?post=716"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}